LCR Measuring Bridge ST2829A
£2,909.96*
Details
+49 421 277 9999
Highlights
- Test frequencies: 20Hz–300kHz
- Resolution: 1mHz, 5-digit frequency input
- Basic Accuracy 0.05%
- Measuring Speed (f ≥10KHz): Fast: 9ms / Medium: 67ms / Slow 187ms
- 150-point list sweep function
- Scanning and graphical analysis based on frequency, AC level and DC bias
- Built-in DC bias voltage source: 10V / 100mA
- Independent DC voltage source: 10V / 50mA
- Optional DC bias current source: 1A
- USB, RS232, Handler, DCI, GPIB, LAN-LXI (option)
Specification
- Measurement parameters: C, L, R, Z, Y, X, B, G, D, Q, θ, DCR, Δ% (Vdc-Idc)
AC Test Level Voltage:
- 5mV–10Vrms
- Resolution: 100µV, 3-digit input
- Accuracy:
- ALC ON: 10% x set current + 2mV
- ALC OFF: 6% x set current + 2mV
AC Test Level Current:
- 50µV–100mA
- Resolution: 1µA, 3-digit input
- Accuracy:
- ALC ON: 10% x set current + 20 µA
- ALC OFF: 6% x set current + 20 µA
- Output impedance: 30Ω, 50Ω, 100Ω
- Calibration function: open / short / load
- Equivalent circuit: serial, parallel
- Range mode: Auto and hold
- Display mode: Direct reading, ΔABS, Δ%
- Trigger Mode: Internal, manual, external, BUS
- Internal DC bias voltage source:
- Voltage/current range: 0V - ±10V / 0mA - ±100mA
- Resolution: 0.5mV / 5µA
- Voltage accuracy: 1% x set set voltage + 5mV
- Optional: 1A Internal DC Bias current source ST9201
- Suitable accessory: External DC Bias Current Source ST1778
- Comparator function 10 bins and bin counters
- Display: 800×480 LCD-display
- Memory: 100 groups of control settings can be saved, 10 sets of gif images
- Interface: USB DEVICE (USBTMC and USBCDC support), USB HOST (FAT16 and FAT32 support), RS232C, HANDLER
- Power supply: Voltage: 99V−121V,198V−242V / Frequency: 47Hz−63Hz
- Working Temperature & Humidity: 0°C − 40°C, ≤90%RH
- Dimensions (W/H/D): 400/132/385 mm
- Weight: 13kg
- CE-conformity: EN 50 191
Measurement display ranges
|Z|, R, X, DCR: | 0.00001Ω - 99.9999MΩ |
|Y|, G, B: | 0.00001nS - 99.9999S |
L: | 0.00001µ - 9.9999kH |
C: | 0.00001pF - 9.99999F |
Q: | 0.0001 - 99999 |
D: | 0.00001 - 9.99999 |
θ(DEG): | -179.999° - 179.999° |
θ(RAD): | -3.14159° - 3.14159° |
Δ%: | -999.999° - 999.999° |
What's in the box
- ST26011A Kelvin-Terminal-Test-Leads
- ST26048 4-terminal test fixture
- ST26010 Gilded shorting plate
- Operation manual
- Power cord
- EN - ST2829 User Manual (4.55 MB)
- EN - ST2829A Handler (919.16 KB)
- DE - ST2829A Datenblatt (353.26 KB)
- DE - ST2829 Bedienungsanleitung (4.96 MB)
Specifications |
|||||
Display | 800xRGBx480 7-inch TFT LCD display | ||||
Frequency of test signal | ST2829A | 20Hz - 300kHz | |||
ST2829B | 20Hz - 500kHz | ||||
ST2829C | 20Hz - 1MHz | ||||
Minimum resolution | 1mHz, 5-digit frequency input | ||||
Accuracy | 0.01% | ||||
AC Level | Voltage range of test signal | 5mV - 10Vrms | |||
Minimum resolution of voltage | 100µV, 3-digit input | ||||
Accuracy | ALC ON | 10% x set voltage + 2mV | |||
ALC OFF | 6% x set voltage + 2mV | ||||
Current range of test signal | 50µA - 100mA | ||||
Minimum resolution of current | 1µA, 3-digit input | ||||
Accuracy | ALC ON | 10% x set current + 20µA | |||
ALC OFF | 6% x set current+ 20µA | ||||
DC bias voltage source | Voltage/Current range | 0V - ±10V / 0mA - ±100mA | |||
Resolution | 0.5mV / 5µA | ||||
Voltage accuracy | 1% x set voltage + 5mV | ||||
ISO ON | Be used for the bias test of inductance and transformer | ||||
AC Source impedance | ISO ON | 100Ω | |||
ISO OFF | 30Ω, 50Ω 100Ω selectable | ||||
DCR Source impedance | 30Ω, 50Ω, 100Ω selectable | ||||
DC Independent voltage source | Voltage/Current range | 0V - ±10V / 0mA - ±50mA | |||
Resolution | 0.5mV / 5µA | ||||
Voltage accuracy | 1% x set voltage + 5mV | ||||
Output resistance | 100Ω | ||||
Test parameters of LCR | |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Vdc-Idc | ||||
Parameter display of test page | Two sets of main/sub parameters, the second set can be set as ON/OFF; There can be 10 pages of list sweep with 15 points per page at most; Multiple parameters continuous sweep graphical analysis. |
||||
Basic accuracy | LCR test parameter | 0.05% | |||
Calibration conditions | Warm-up time ≥ 30 seconds; Environment temperature: 23±5°C; Signal voltage: 0.3Vrms-1Vrms Zeroing: After OPEN or SHORT; Length of test cable: 0m |
||||
Measurement time (≥10 kHz) | Fast: 9 ms / time Medium: 67 ms / time Slow: 187 ms / time plus the refresh time of the characters on the display |
||||
Display range of LCR parameter | |Z|, R, X, DCR | 0.00001Ω - 99.9999MΩ | |||
|Y|, G, B | 0.00001µs - 99.9999s | ||||
C | 0.00001pF - 9.99999F | ||||
L | 0.00001µH - 99.9999kH | ||||
D | 0.00001 - 99999.9 | ||||
Q | 0.00001 - 9.99999 | ||||
θ(DEG) | -179.999° - 179.999° | ||||
θ(RAD) | -3.14159 - 3.14159 | ||||
Δ% | -999.999% - 999.999% | ||||
Equivalent circuit | Serial, Parallel | ||||
Range mode | Auto, Hold | ||||
Trigger mode | Internal, Manual, External, Bus | ||||
Average times | 1-256 | ||||
Calibration function | Open, short calibration with full frequency or dot frequency, Load calibration with standard test component | ||||
Math operation | Direct reading, ΔABS, Δ% | ||||
Delay time setup | 0-999, minimum resolution: 100µs | ||||
Comparator | 10-bin sorting, BIN1-BIN9, NG, AUX | ||||
Bin counter | |||||
PASS/FAIL on front panel, LED indication | |||||
List sweep | • There can be 10 pages of list sweep with 15 points per page at most. • List sweep of frequency, AC voltage/ current, internal/external DC bias voltage/current and independent DC source voltage can be performed on each page. Each sweep point can be sorted separately. |
||||
Graphical analysis | • Graph scanning and analysis of frequency, AC level, and DC bias can be performed. •Set the sweep start point, end point and each sweep point. • Display the maximum value, minimum value and show data of the chosen sweep point • Scanning graphs can be stored into internal or external USB memory. |
||||
Internal nonvolatile memory | 100 sets of LCRZ setting files 201 times test results 10 sets of GIF image, CSV data files | ||||
External USB memory | • GIF image, CSV data files • LCRZ setting files • Test data can be stored via USB memory directly. |
||||
Interface | 1A bias current source | 1A DC bias current source (optional, ST2901) can be installed | |||
I/O interface | HANDLER on rear panel | ||||
SCI | USB, RS232C | ||||
PCI | GPIB (optional) | ||||
Memory interface | USB HOST (front panel) | ||||
Bias current source control interface DCI | External DC bias current source can be controlled by using DCI interface. The maximum bias current can reach 120A. | ||||
Standard configuration | |||||
General Specifications | |||||
Operating temperature and humidity | 0°C - 40°C, ≤ 90%RH | ||||
Power supply | Voltage | 99V - 121V, 198V - 242V AC | |||
Frequency | 47Hz - 63Hz | ||||
Power Consumption | Max. 80 VA | ||||
Dimension (WxHxD) | 400mm x 132mm x 385mm | ||||
Weight | Approx.13 kg |
Related products
- Standard-compliant, multi-vendor calibration based onISO 17025
- Measuring devices: VDE devices, LCR meter, safety tester, bridges, ...
- Traceable to DKD
- Cleaning and adjustment
- Repair service
- Plug & Play Ansteuerung für Sourcetronic LCR Messgeräte
- Komplette Fernsteuerung der Messgeräte
- Komfortable Oberfläche im JAVA "look&feel"
- Automatisch skalierende graphische Kurven-Verläufe
- Linear & logarithmisch
- Extra "Live"-Daten Fenster
- Automatische Nullkalibrierung Short / Open
- Spezialfunktion "Frequency Sweep in graphischer Darstellung
- Benutzerdefinierbarer Grenzwertvergleich
- Robust 19" mounting frame
- Metal powder coated
- Device mounting front
- Devices: ST2829, ST2829XX, ST2883
- Color: RAL7035 light gray
- Height: 4 HE
- Devices: ST2829A/-B/-C, ST2829AX /-BX /-CX
- Extension of DC bias
- Current: ±1 A DC
- Extension of GPIB interface
- For hipot tester,
Impedanz analyzer, ohmmeter,
LCR meter, multimeter
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 42V DC
- SMD test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- 4-wire technology
- Kelvin-leads with BNC-Terminal
- Isolation of soft PVC
- Multi colored cable (red and black)
- Strain relief and bend protection
- Frequency up to 300kHz
- Kelvin Clip Terminal for precise LCR measurement
- 4 BNC Connectors
- 2 sturdy tong contacts
- Fine tooth profile gold plate brass
- No ferromagnetic parts
- Can be used with commercial LCR bridges
- DC Bias Current Source: 0A up to 120A
- Output voltage 0 - 35V
- Frequency bandwidth: 50Hz - 200Hz
- Accuracy: 1%
- Resolution up to: 5mA
- For wide range of LCR Meter
- Connection cable GPIB
- IEEE 488.2, 24 pin
- LCR meter, milliohm meter, multimeter
- Devices: ST2830, ST2827, ST2829
- Distance between the BNC sockets: 22mm
- Cable length: 0.8m
- Adapter for zero calibration to actual component size
- Golden shorting plate
- Measuring device zero claibration
- For all LCR test fixture
- Devices: LCR Meter ST2827A/C, ST2829A/C
- Robust transport case
- Aluminium frame lid can be opened
- Equipment compartment with punctual foam lining
- Clearly arranged accessory compartments
- Highest transport safety
- 2 central butterfly locks at the front
- 2 locking hinges at the rear
- 1 HighEnd case handle at the front
- 4-Wire-Kelvin-Test-Leads
- Sophisticated BNC plugs
- distance between the BNC sockets: 22mm
- Alligator style clips (red / black)
- Gilded contacts
- For multimeter and LCR Meters