Insulation tester MD 1035X
£1,227.59*
Details
+49 421 277 9999
Highlights
- 1.000 V Megohmmeter
- Insulation test 10 kΩ to 1 TΩ
- Digital & bar-graph reading
- Automatic measurement:
Dielectric Absorption Index (DAI),
Polarization Index (PI) - Chronometer up to 90 minutes
- Step voltage test
- Built-in printer (option)
- 4000 readings memory
- Isolated USB data port
- Software for data management
- Rechargeable battery
The MD1035x is a smart, microprocessor-controlled, 1 kV insulation tester. Besides the conventional measurement of insulation resistances up to 1 TΩ, its advanced features allow to automatically measure both the Polarization Index and Dielectric Absorption Index, thus significantly simplifying testing of transformers. This insulation tester is a portable, battery-powered equipment. Test voltage may be chosen from 100 V to 1 kV in 50 V increments. Due to its measurement principle (actual voltage and current readings) the accuracy of resistance measurement is not affected by any test voltage error.
The built-in chronometer automatically counts the elapsed time since the start of measurement. Measured values are transmitted through the USB interface and are printed in the built-in printer (optional) as a registration of the performed test. Furthermore, the measured values are stored in a non-volatile internal memory. Up to 4000 measured values may be stored, to be transferred afterward to a computer running the T-Logger program. This software allows a further analysis of the test results, including a graphical representation and automatic report generation. The real time clock and calendar, and the sequential test number, facilitates the identification of each test, and the organization of a predictive maintenance system by trend analysis. Some other advanced features are useful to run the most sophisticated insulation analysis. Configurable Pass-Fail and timed measurements are automatically performed, with a very simple and user-friendly setup. The measurement parameters are stored in the non-volatile memory for an easy configuration.
In order to guarantee the operator safety, the cabinet is made of a high breakdown strength plastic. Output terminals are placed in the furthest and most protected area of the equipment. A light indicator shows high-voltage presence and is switched-off when the capacities (both internal and external) are discharged up to reaching a safe value. The MD1035x is powered using a rechargeable LFP battery and has an automatic charger that may be connected to 100 - 240 V mains supply (through an AC Adapter). The cabinet is strong and lightweight, easy to carry, impact-resistant and suitable to be used under severe weather conditions. Thus the instrument supplies very reliable and accurate measurements both in laboratory and out in the field.
TEST VOLTAGES
- 100 V, 250 V, 500 V, 1000 V directly, one button selectable
- 100 V to 1 kV in 50 V increments
- DC, negative
MAXIMUM RESISTANCE READING
- 1 TΩ @ 1 kV
SHORT CIRCUIT CURRENT
- 1.5 ± 0.5 mA
TEST VOLTAGES ACCURACY
- ± 3% of nominal test voltages on 10 GΩ
EQUIPMENT BASIC ACCURACY
- ± 5% of reading ± 3 digits
- (1 MΩ to 500 GΩ at any test voltage)
ADVANCED FEATURES
- Automated Polarization Index calculation
- Automated Dielectric Absorption Ratio calculation
- Programmable Pass-Fail test
- Programmable Timer.
BUILT-IN PRINTER (OPTIONAL)
- Prints elapsed time, actual voltage and resistance measured each 15 seconds
BUILT-IN MEMORY
- Stores up to 4000 measured values
INTERFACE
- USB
BUILT-IN CHRONOMETER
- Shows elapsed time in mm:ss format. Count starts automatically for each measurement
REAL TIME CLOCK AND CALENDAR
- Allows a reliable identification for each test
ENVIRONMENTAL PROTECTION
- IP54 with closed lid
SAFETY CLASS
- In accordance with IEC 61010-1
E.M.C.
- In accordance with IEC 61326-1
ELECTROSTATIC IMMUNITY
- In accordance with IEC 61000-4-2
ELECTROMAGNETIC IRRADIATION IMMUNITY
- In accordance with IEC 61000-4-3
POWER SUPPLY
- Internal rechargeable LFP battery (LiFePO4 12 V - 3000 mAh)
BATTERY CHARGER
- 12 V - 2.0 A
OPERATING TEMPERATURE RANGE
- 23°F to 122°F (-5°C to 50°C)
STORAGE TEMPERATURE RANGE
- -13°F to 149°F (-25°C to 65°C)
HUMIDITY RANGE
- 95% RH (non condensing)
EQUIPMENT WEIGHT
- Approx. 5.96 lb (2.7 kg)
DIMENSIONS
- 10.78" x 9.84" x 4.88" (274 x 250 x 124 mm)
INCLUDED ACCESSORIES
- 2 Measuring test leads, 5.90 ft (1.8 meters)
- 1 Guard test lead, 5.90 ft (1.8 meters)
- 1 AC Adapter
- 1 USB communication cable
- 1 T-Logger user license
- 1 User guide
- 1 Carrying bag
Related products
- Standard-compliant, multi-vendor calibration based onISO 17025
- Several measurement ranges
- Insulation tester
- Traceable to DKD
- Cleaning and adjustment
- Repair service