Measurement Technology
- Rental Equipment
- Battery tester
- Calibration Services
- Capacitance Meter
- DC Bias Current Source
- Digital Power Meter
- Earth Testers
- Ground Bond Tester
- HV Probe
- High Voltage Relays
- Hipot Testers
- Impedance Analyzer
- Insulation Testers
- LCR Meters
- Measurement Software
- Megohmmeter
- Microohmmeters
- Milliohmmeters
- Multimeters
- Relay Matrix
- Safety Testers
- Surge Testers
- Test Systems
- Transformer Testers
- Transport Cases
Hipot Tester ST9201S (Rental device)
Product number:
63988
EAN:
4260409229112
£289.48*
Goods expected soon
Details
Fachberatung unter
+49 421 277 9999
+49 421 277 9999
Print
Description
Product information "Hipot Tester ST9201S (Rental device)"
Highlights
- AC / DC withstanding voltage and insulation tester
- 240×64 Dot-matrix graphic LCD display
- Fast discharge and arc detection function
- Body protection function
- Built-in 8-channel matrix scanner for convenient use
- Set voltage rising time, test time, and voltage dropping time randomly for different load, DC withstanding voltage current judging & waiting time
- 100 test steps being stored per group, totally 50 groups, and the total testing steps are limited at 500
- Current base number correction function
- RS-232C, Handler and SCAN Interface
Technical data
- 8-channel matrix scanner
- Memory: 50groups, 100 steps per group, totally 500 steps
- Voltage rise-time: 0.1s - 999s
- Voltage fall-time: 0.1s - 999s
- Voltage wait-time: 0.1s - 99.9s (only for DC) (not 9201)
- Test time setting 0.3s - 999s
- Interfaces: USB, RS232, HANDLER, REMOTE I/O, SCAN
- Power supply: 230V / 50Hz
- Dimensions (W/H/D) : 340/120/438.50 mm
- Weight: 20 kg
- CE - conformity
Test methods
Withstanding voltage test
- Output voltage
- AC: 0.05kV — 5kV ± 1.0% of reading + 5 digit, (50Hz ,60Hz optional)
- DC: 0.05kV — 6kV ± 1.0% of reading + 5 digit (not 9201C)
- Voltage adjustment rate: ≤ 1.0% +10V (rated power)
- Current test range
- AC: 0.1mA - 3mA
- DC: 0.01mA - 10mA
- Test accuracy ± 1.0% of reading+5 digit
- Discharge function: Discharge after test ends (DCW)
Insulation resistance test (not 9201C)
- Output voltage:
- 0.05kV - 1kV ± 1.5% of reading + 5V
- Resistance test range:
- 0.1MΩ - 10GΩ, Current range within 10nA - 10mA
- Resistance test accuracy:
- 500V-1000V 1MΩ - 1GΩ ± 5% of reading + 5 digit / 1GΩ - 10GΩ ± 10% of reading + 5 digit
- 50V-500V 0.1MΩ - 1GΩ ± 10% of reading + 5 digit
- Discharge function: Discharge after test ends
Arc detection
- Measurement range:
- AC: 1mA - 3mA
- DC: 1mA - 10mA
What's in the box:
- ST90003R HV connection cable with test clip
- ST90003B HV Earth connection cable with test clip
- ST90002 HV Test probe
- Factory calibration certificate
- Power cord
- User manual
Downloads
- ST9201S Bedienungsanleitung (0 KB)
Technical data
Technical specification |
|||||||||||||
Model | ST9201 | ST9201S | ST9201B | ST9201C | |||||||||
Output voltage |
|||||||||||||
AC | Voltage | 0.05KV - 5KV | |||||||||||
Frequency | 50Hz, 60Hz selectable | ||||||||||||
Output power | 150VA (5kV/30mA) | 100VA (5kV/20mA) | |||||||||||
DC | Voltage | 0.05KV - 6KV | 0.5KV - 6KV | - | |||||||||
Output power | 50VA (5kV/10mA) | 25VA (5kV/5mA) | - | ||||||||||
Discharge function | Automatically after end of test | - | |||||||||||
IR | Voltage | 50V-1000V | - | ||||||||||
Output power | 10 VA (1000V/10mA) | - | |||||||||||
Discharge function | Automatically after end of test | - | |||||||||||
8 Channel Matrix | - | Yes | - | ||||||||||
Voltage indication |
|||||||||||||
Range | Range of voltage | 0.00kV – 6.00kV AC/DC | |||||||||||
Accuracy | ±(1.0% of reading +2V) | ||||||||||||
Range | AC | 0.1mA – 30mA | 0.1mA – 20mA | ||||||||||
DC | 0.01mA – 10mA | 0.01mA – 5mA | - | ||||||||||
Accuracy | ±(1% of reading +10digits) (after correction) | ||||||||||||
ARC | AC | 1mA – 15mA | 1mA – 15mA | ||||||||||
DC | 1mA – 10mA | 1mA – 5mA | |||||||||||
Insulation resistance indication | |||||||||||||
Resistance measuring range | 0.01MΩ– 9.99GΩ, (Strom: 10nA – 10mA) | - | |||||||||||
Accuracy | ±(5% of reading + 5digits) | - | |||||||||||
General specification |
|||||||||||||
Voltage rise-time | 0.1s - 999s | ||||||||||||
Voltage fall-time | 0.1s - 999s | ||||||||||||
Voltage wait-time (DC) | 0.1s - 99.9s (only for DC) | ||||||||||||
Test time setting | 0.3s - 999s | ||||||||||||
More features | Fast charge, body protection function, handler, RS-232, GPIB interface, USB host for memory sticks |