Frequency Inverter ST150 2.2KW 230V
£128.41*
Details
+49 421 277 9999
Highlights
- Power: 2.2 KW
- Rated input current: 23 A
- Rated output current: 10 A
- Voltage:
- 230VAC (220V-15% - 240V+10%, mains: 1-phase/motor: 3-phase).
- Mains frequency: 50/60Hz, +-5%.
- German instruction manual
- Weight: 1.1 Kg
- Dimensions (H/W/D): 185 / 72 / 134 mm
- Top-hat rail mounting
- "Plug & Play":
- First-class pre-configured
- Short installation time
- Easy intuitive commissioning
- Flexible digital and analogue I/Os
- Overload capability: 1min. 150% / 2 sec. 180%.
- Boost function for operation from approx. 1Hz, 150% torque at 0.5Hz in vector mode
- Integrated brake chopper (minimum resistance 32 Ohm)
- Auto slip compensation
- Advanced PID control
Inputs
Digital inputs |
|
Programmable digital inputs: | 5, with 44 input functions |
Tension level: | 0 - 24VDC |
Logik: | NPN (active when the input is connected to GND) |
Maximum voltage at the input: | 30VDC |
Number of programmable pulse inputs: | - |
Maximum input frequency: | 1kHz |
Resolution for frequency control: | - |
Analogue inputs |
|
Number of analogue inputs: | 1 |
Type of inputs: | AI 1: 0-10V / 0-20mA |
Resolution for frequency control | max. frequency * 0.025%, tolerance ±0.5%@25°C |
Outputs
Output (U,V,W) |
|
Control modes: | V/f characteristic / vector control o. PG |
Output voltage: | 0 - 100% of the mains supply |
Output frequency: |
0 - 300Hz vector control
|
Nominal motor voltage: | 220/230V |
Ramp times: | 0,0 - 6500,0s |
Ramp functions: | Linear / S-curve |
Overload function: | 150% for one minute 180% for 2 seconds |
Carrier frequency: | 0.5kHz - 16.0kHz adjustable |
V/f curve modes: | Linear / Square / Adjustable |
Digital output / pulse output |
|
Programmable outputs: | - |
Tension level: | - |
Logic: | - |
Minimum output frequency: | - |
Maximum output frequency: | - |
Relay outputs |
|
Programmable outputs: | 1 |
Terminal number: | TA-TC: N/O contact |
Maximum power AC: | 250VAC / 5A |
Maximum power DC: | 30VDC / 5A |
Number of functions: | 35 |
Analogue outputs |
|
Programmable outputs: | 1 |
Voltage range: | 0 - 10VDC max. 5mA |
Electricity sector: | 0 - 20mA max. load 250Ohm |
Tolerance | ±0.5 at 25°C and ≥ 5V/10mA |
Number of functions: | 13 |
Modbus |
|
RS485 | Integrated |
Integrated protection concept
- 100 % earth fault protection
- Over- and undervoltage protection
- Over- and undercurrent protection
- Temperature monitoring
- Protection against overtemperature
- Protection against motor overload
- Overvoltage blocker
- External stop signal
- Stop when communication is interrupted
- Abnormalities in the PID signal
- "Power module and IGBT output stage
- Cooling type: fan cooling
- Password protection
- Auto self-test after switching on again
- 15ms mains failure bridging
Display and functions
- Display:
- Frequency, current, voltage, torque, PID, etc.
- Error messages
- Key lock
- Automatic functions:
- Calibration of motor data
- Voltage readjustment (AVR)
- Integrated runtime measurement and error memory
- Active current limiting
- Restart in case of mains failure
- Slip compensation
- DC braking function (duration, strength, frequency)
- JOG control
Types of enclosures and dimensions
Rated voltage |
Output power [kW] |
Rated input current [A] |
Rated output current [A] |
Housing dimensions (LxWxH) [mm] |
Installation dimensions (AxBxdxE)
|
Weight (brutto / netto) [kg] |
1-phase 230V | 2.2 | 23 | 10 | 185 x 72 x 134 | 175 x 45 x Ø5 x 82
|
1.3 / 1.1 |
Surroundings
- Temperature range -10°C to +40°C without power reduction
- Storage temperature -20°C to +65°C
- Humidity up to 90% RF - without condensation
- Operating altitude up to 1,000m above sea level without power reduction
- Safety level according to IEC61800-5
- Electromagnetic compatibility according to IEC61800-3
- Vibration test under 5.9m/s²=0.6g
- Protection class: IP20 (EN 60529), NEMA 1
- RoHS compliant
- CE-compliant
Scope of delivery
- Frequency converter ST150
- Detailed, German operating instructions
More functions
- Nominal motor frequency 50Hz and 60Hz
- Forward and reverse operation
- Controller enable Control panel/terminals/bus
- 16 fixed speeds selectable via switching inputs
- 7 different ways to control the speed
- PWM clock frequency adjustable in 0.1 kHz steps: 0.5 kHz-16 kHz
- "Plug & Play
- Reduced motor noise due to precise PWM function
- Avoidance of vibrations due to selectable blocking frequencies
- ST150 User Manual (1.79 MB)
- ST150 EPLAN Makros + DXF (7.92 MB)
- ST150 Bedienungsanleitung (2.23 MB)
Accessiores
- Telefonische Beratung
- Auslegung und Inbetriebnahme
- Individuelle Parametrierung
- Programmbetrieb
- Parameterliste
- Resistance: 75 Ω
- Rated power: 800 W (continuous braking power with appropriate heat dissipation)
- Operating voltage range: up to 400 V
- IP Grade: IP00/IP33
- Weather resistant and vibration resistant
- Easy insatallation
- Rated voltage: 3x 400 Vac
- Voltage range: 3 x 0 - 500 Vac
- Rated current: 10 A
- for motor rated output approx. 4,00 kW
- Inductance: 0,640 mH
- Rated frequency: 0 - 50 Hz
- Switching frequency: 3 - 8 kHz
- Price per meter
- Number of cores and mm² per conductor: 4G2.5 (3x 2.5mm² black and 1x 2.5 mm² PE)
- Outer diameter in mm: 12.4
- Connecting cable for electric drives with high output
- EMC optimized and double shielded
- 3 + 3 symmetry reduces common mode interference
- Bemessungsspannung: 250 Vac
- Spannungsbereich: 0 - 250 Vac
- Bemessungsstrom: 25 A
- Ableitstrom (50Hz): <3,00mA
- Bemessungsfrequenz: 50 - 60 Hz
- Überlastfähigkeit: 150%, kurzzeitig