Transformer Tester ST2829AX
€3,280.00*
Details
+49 421 277 9999
Highlights
- Frequencies: 20Hz - 200kHz
- Basic Accuracy: 0.05%
- 800x480 LCD-color-display
- Measuring Speed: 13ms
- Interfaces: LAN-LXI, USB, RS232, Handler, DCI, (GPIB option)
- LCR option
Specification
- 7-inch 16:9 TFT LCD display with a resolution of 800x480
- Up to 1MHz test frequency, 0.5mHz resolution
- Signal amplitude range: 5mV to 10Vrms, 100μVVresolution
- Test speed is up to 75meas/sec
- Built-in 0-100mA/0-10V bias source (standard) or 1A bias source (optional)
- Diode P/N characteristic detection can test all parameters of network transformer
- Improved high turn ratio and weak coupling transformer test ability
- Improved DCR test ability for low-ohm winding
- Flexible time-labeling system: time of file setting, calibration and deduction can be saved
- Sort the selected scanning parameters
- Flexible deviation and deduction modes
- Multiple handling ways for FAIL cases
- Single parameter test cycle can be used to test a separate winding
- Internal memory for up to 200 setting files and external USB memory for more
- Test data and graphs can be saved as CSV, GIF format to USB memory
- The built-in software provides analysis abilities, such as Cpk, Cp and Ck
- Bar-code reading function can be used to select a setting file or to manage the type of test products
- Parameter setting files are compatible with ST2818X/ST2819X
- Program setting files with your local PC
- Upgrade operation software of USB HOST and RS232C online
- Multiple interfaces are optional for PC communication
- To network multiple testers through LAN-LXI interface
What's in the box
- ST1901B Manual transformer scanning fixture
- ST26005B 4-terminal test fixture
- ST26011A 4-terminal Kelvin test clip leads
- ST26004B 2-terminal test clip leads
- ST26016 Transformer scanning control cable
- ST1901-001 Foot switch
- ST26010 Gilding short board
- EN - ST2829 User Manual (4.55 MB)
- DE - ST2829 Bedienungsanleitung (4.96 MB)
- EN - ST2829AX Handler (1010.75 KB)
- EN - ST2829AX Parameterization with ST1901B (1.36 MB)
- DE - ST2829AX Beispiel Parametrierung mit ST1901B (503.31 KB)
Technical Specifications |
|||
Model | ST2829AX | 20-Pin Transformer Scanning Test + LCR Test (Optional) ST2829X provides a 10-hour function-experience for LCR test. The experience version will be automatically turned off after 10 hours of using. If you do need this function, please contact our salesmen or distributors and provide your detailed instrument serial number. |
|
ST2829BX | |||
ST2829CX | |||
Basic accuracy (See operation manual) |
LCRZ | 0.05% | |
DCR, Turn ratio |
0.1% | ||
Calibration | Warm-up time = 30 minutes, Environment temperature: 23±5ºC, Signal voltage: 0.3Vrms – 1Vrms Zeroing: After OPEN or SHORT Length of test cable: 0 m |
||
Frequency of test signal |
ST2829AX | Range: 20Hz - 200kHz | Min. resolution: 0.5mHz Accuracy: 0.01% |
ST2829BX | Range: 20Hz - 500kHz | ||
ST2829CX | Range: 20Hz - 1MHz | ||
Output impedance of signal source | 10Ω, 30 Ω, 50Ω, 100Ω(selectable), ±1% @1kHz | ||
Level of AC test signal |
Normal level | 5mV - 10Vrms | Min. resolution: 100µV, accuracy: 10%xset voltage+2mV |
50µA - 100mArms | Min. resolution: 1µA | ||
Constant level | 10mV - 5Vrms | Min. resolution: 100µV, accuracy: 10%x set voltage+2mV |
|
100µA - 50mArms | Min. resolution: 1µA | ||
DC bias voltage source |
0V - ± 10V | Min. resolution: 0.5mV, accuracy: 1%x set voltage+5mV | |
0mA - ± 100mA | Min. resolution: 0.5µA | ||
DC constant current source (optional) (for diode P/N characteristic test) |
0 - ± 120mA | Min. resolution: 0.5mV, accuracy: 1%x set voltage+5mV | |
DC bias current source (optional, ST2901) |
0 - ± 1A | Min. resolution: 0.5mA, accuracy: 1%x set voltage+2mA Load open voltage: = 9 V |
|
Transformer test parameters | Turn Ratio, Turns, Phase, L, C, Lk, Q, ACR, DCR, Balance, Pin Short, Diode P/N | ||
LCR test parameters | |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR, Turn-Ratio,Phase, Lk | ||
Display range of DCR | 0.00001 Ω - 999.999 MΩ | ||
Display range of turn ratio | 1:0.001 - 1000:1 | ||
Display ranges of LCR parameters | |Z|, R, X | 0.00001Ω - 99.9999MΩ | |
|Y|, G, B | 0.00001µs - 99.9999s | ||
C | 0.00001pF - 9.99999F | ||
L | 0.00001µH - 99.9999kH | ||
D | 0.00001 - 9.99999 | ||
Q | 0.00001 - 99999.9 | ||
θ (DEG) | -179.999º - 179.999º | ||
θ(RAD) | -3.14159 - 3.14159 | ||
Δ % | -999.999% - 999.999% | ||
Diode test | Positive voltage | 0 - 9.9999 V | |
Negative current | 0 - 99.999 mA | ||
Measurement speed (=10 kHz) |
Fast: 75meas/ sec(13ms), Medium: 11meas/ sec (90ms), Slow: 2.7meas/ sec (370ms) | ||
Equivalent circuit | Serial, Parallel | ||
Range mode | Auto, Hold | ||
Trigger mode | Internal, Manual, External, Bus | ||
Average times | 1 - 255 | ||
Calibration function | Open, Short, Load | ||
Math operation | Direct reading, ΔABS, Δ% | ||
Delay time | 0 - 60.000s, 1ms resolution | ||
Comparator | 10-bin sorting, BIN1~BIN9, NG, AUX | ||
Bin counter | |||
PASS/FAIL on front panel, LED indication on scanning fixture | |||
Memory | 200 sets of LCRZ setting files 200 sets of setting files for transformer scanning 10 sets of GIF files |
||
Interface | Control interface | HANDLER (optional) on rear panel SCANNER(compatible with TH1901A/B, TH1805A/B transformer scanning fixtures) |
|
Communication interface |
LAN-LXI, GPIB (optional), USB HOST, RS232C | ||
Memory interface | USB HOST (USB memory or bar-code scanning) | ||
General Specifications |
|||
Operating environment |
Temperature | 0°C - 40°C, | |
Humidity | ≤ 90%RH | ||
Power supply | Voltage | 99V-121V AC, 198V-242V AC | |
Frequency | 47Hz - 63Hz | ||
Consumption | Max. 80 VA | ||
Dimension (W×H×D) | 400mm×132mm×385mm | ||
Weight | Approx. 13 kg |
Related products
- Standard-compliant, multi-vendor calibration based onISO 17025
- Measuring devices: VDE devices, LCR meter, safety tester, bridges, ...
- Traceable to DKD
- Cleaning and adjustment
- Repair service
- Robust 19" mounting frame
- Metal powder coated
- Device mounting front
- Devices: ST2829, ST2829XX, ST2883
- Color: RAL7035 light gray
- Height: 4 HE
- Devices: ST2830, ST2827, ST2829
- Distance between the BNC sockets: 22mm
- Cable length: 0.8m
- Adapter for zero calibration to actual component size
- 4-wire technology
- Kelvin-leads with BNC-Terminal
- Isolation of soft PVC
- Multi colored cable (red and black)
- Strain relief and bend protection
- Manuel test fixture for 20 knots
- Trigger mode: 4 test clips
- Easy operation, also for semi-skilled workers
- Quick in progress
- 4-Wire-Kelvin-Test-Leads
- Sophisticated BNC plugs
- distance between the BNC sockets: 22mm
- Alligator style clips (red / black)
- Gilded contacts
- For multimeter and LCR Meters
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 42V DC
- SMD test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- Pneumatic test fixture for 20 pins
- Trigger mode: 4 test clips
- Easy operation, also for semi-skilled workers
- Interface: 24VDC handler
- Inductor core test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- Devices: ST2829AX, ST2829AX-24, ST2829AX-48, ST2829BX, ST2829CX
- Robust transport case
- Aluminium frame lid can be opened
- Equipment compartment with punctual foam lining
- Extra compartment for transformer measuring adapter
- Clearly arranged accessory compartments
- Highest transport safety
- 2 central butterfly locks at the front
- 2 locking hinges at the rear
- 1 HighEnd case handle at the front
- Inserts for test fixture ST26005B
- Measuring of axial components
- LCR meter with test fixture
- Frequency up to 300kHz
- Kelvin Clip Terminal for precise LCR measurement
- 4 BNC Connectors
- 2 sturdy tong contacts
- Fine tooth profile gold plate brass
- No ferromagnetic parts
- Can be used with commercial LCR bridges
- Devices: ST2829A/-B/-C, ST2829AX /-BX /-CX
- Extension of DC bias
- Current: ±1 A DC
- Golden shorting plate
- Measuring device zero claibration