Precision LCR Meter ST2839
Price on request
Details
+49 421 277 9999
Highlights
- Test Frequency: 20Hz - 10MHz
- High accuracy:Auto-balance bridge technology, 4-terminal pair
- Basic accuracy: 0,05%
- High stability and consistency:Up to 15 test ranges
- High resolution:7- inch, 800×600
- Interfaces: RS232, USB HOST, USB DEVICE, LAN, HANDER, SCANNER, Temperature Input Sensor, GPIB (optional)
- 201 Points List Sweep Function
- High speed:Up to 7.7ms
- Simultaneous testing for Ls-Rdc
Technical Data
- 7-inch TFT LCD display 800XRGBX600
- Up to 10MHz Testfrequency
- Highest resolution: 1mHz
- Test level:
- AC voltage: 20Hz — 2MHz:5mV — 2Vrms, 2MHz — 10MHz:5mV — 1Vrms, 100 μ V resolution
- AC current: 20Hz — 2MHz: 50uA—20mArms, 2MHz — 10MHz:50uA—10mArms, 1 μ A resolution
- DC Spannung: 100mV - 2V
- Internal DC Bias 0-100mA / 0-40V
- DC voltage source: -10 V - 10V
- Output impedance: 100 Ohm
- Multi-parameter Graphic Sweep Function
- Parameters: FREQ, ACV, ACV/I, DCV/I, DC voltage source
- Type: Logarithm, linearity
- Sweep points: 51, 101, 201, 401 or 801
- Varactor diode automatic polarity function
- 10 bins sorting, sorting result with sound and light alarm
- Storage space:
- Internal: 40 groups of setting files
- External: 500 groups of setting files, data log files and image files
- Test parameters: Cp/Cs, Lp/Ls, Rp/Rs, |Z|, |Y|, R, X, G, B, θ, D, Q, Vac, Iac, Rdc, Vdc, Idc
- Accuracy:
- 1kHz: 0.05%
- 1MHz: 0.05%
- 2MHz: 0.1%
- 5MHz: 0.5%
- 10MHz: 1.0%
- Calibration settings: OPEN, SHORT, LOAD
- Range selection: AUTO, HOLD
- Trigger Mode: Internal, External, Manuelly and BUS
- Cable length: 0, 1, 2, 3, 4 m
- Test data and graphics can be saved as GIF format on USB memory
- High compatibility: Support SCPI commands, compatible with KEYSIGHT E4980A, E4980AL, HP4284A etc.
- Input voltage: Optional 100-120VAC / 198-242VAC, 47-63Hz
- Dimensions (mm): 400(B) x 132(H) x425(T)
- Weight: 15 kg
Accessories
- ST26010BS Gold-plated short circuit board ST26047 Test fixture
- ST26005C Four-terminal test fixture
- User manual
- Power cord
- EN - ST2839 User Manual (2.97 MB)
Related products
- SMD test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- 4-Wire-Kelvin-Test-Leads
- Sophisticated BNC plugs
- distance between the BNC sockets: 22mm
- Alligator style clips (red / black)
- Gilded contacts
- For multimeter and LCR Meters
- Devices: ST2830, ST2827, ST2829
- Distance between the BNC sockets: 22mm
- Cable length: 0.8m
- Adapter for zero calibration to actual component size
- Golden shorting plate
- Measuring device zero claibration
- For all LCR test fixture
- Provide 20A of constant current output for single one
- Slave machine for connection with ST1778A
- Support 6 machines at most and reach 120A of constant current output
- DC Bias Current Source: 0A up to 120A
- Output voltage 0 - 35V
- Frequency bandwidth: 50Hz - 200Hz
- Accuracy: 1%
- Resolution up to: 5mA
- For wide range of LCR Meter
- Inductor core test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 42V DC