Precision LCR Meter ST2838
Price on request
Details
+49 421 277 9999
Highlights
- Frequencies: 20Hz - 2MHz
- Basic Accuracy: 0.05%
- 800x600 LCD-color-display
- Measuring Speed: 13ms
- Interfaces: RS232, USB DEVICE, LAN-LXI, HANDER, GPIB (Optional), SCANER(Optional), external DC BIAS
- 201 Points List Sweep Function
- Test speed: up to 5.6 ms
Specification
- 7-inch 16:9 TFT LCD display with a resolution of 800x600
- Up to 2MHz test frequency
- Resolution up to 0.1mHz
- AC signal amplitude range: 5mV to 2Vrms resolution
- AC signal current range: 50µArms -- 20mArms
- Test speed is up to 75meas/sec
- Built-in 0-100mA/0-10V DC bias source
- Multi-parameter Graphic Sweep Function
- Arithmetical operation
- 10 bins sorting, sorting result with sound and light alarm
- Huge storage space:
- Internal: 100 groups of setting files, 10 groups of gif image files
- External: 100 groups of setting files through USB storage
- Test parameters: Cp-D, Cp-Q, Cp-G, Cp-Rp, Cs-D, Cs-Q, Cs-Rs, Lp-D, Lp-Q, Lp-G, Lp-Rp, Lp-Rdc, Ls-D, Ls-Q, Ls-Rs, Ls-Rdc, Rdc, R-X, Z-θd, Z-θr, G-B, Y-θd, Y-θr, Vdc-Idc
- Mathematics function: A(X+B)+C, X is test parameter, A, B,C is input parameter
- Equivalent circuit: series, parallel
- Calibration function: OPEN, SHORT, LOAD
- Range selection: AUTO, HOLD
- Improved high turn ratio and weak coupling transformer test ability
- Flexible time-labeling system: time of file setting, calibration and deduction can be saved
- Flexible deviation and deduction modes
- Multiple handling ways for FAIL cases
- Single parameter test cycle can be used to test a separate winding
- Test data and graphs can be saved as GIF format to USB memory
- The built-in software provides analysis abilities, such as Cpk, Cp and Ck
- Bar-code reading function can be used to select a setting file or to manage the type of test products
- Support SCPI commands, compatible with KEYSIGHT E4980A, E4980AL, HP4284A etc.
- To network multiple testers through LAN-LXI interface
- Dimension (mm): 400(W) x 132(H) x425(D)
- Weight: 15kg
Measurement display ranges
Test display range | a 1x10-18 ; E 1x1018 |
Cs, Cp | ±1.000000 aF -- 999.9999 EF |
Ls, Lp | ±1.000000 aH -- 999.9999 EH |
D | ±0.000001 -- 9.999999 |
Q | ±0.01 -- 99999.99 |
R, Rs, Rp, X, Z, Rdc | ±1.000000 aΩ -- 999.9999 EΩ |
G,B,Y | ±1.000000 aS -- 999.9999 ES |
Vdc | ±1.000000 aV -- 999.9999 EV |
Idc | ±1.000000 aA -- 999.9999 EA |
θ r | ±1.000000 a rad -- 3.141593 rad |
θ d | ±0.0001 deg -- 180.0000 deg |
Δ % | ±0.0001% -- 999.9999% |
t | -99.99°C -- 1000.00°C |
What's in the box
- ST26011B Kelvin clip terminal
- ST26005C 4-terminal test fixture
- Operation manual
- Power cord
- ST2838 User Manual (2.94 MB)
Model | ST2838 | ST2838H | ST2838A | |||||
Test Signal Source | ||||||||
Output impedance | 100Ω, ±1% @1kHz | |||||||
Frequency | Range | 20Hz - 2MHz | 20Hz - 1Mhz | |||||
Resolution | 20.0000Hz - 99.9999Hz, 0.1mHz | |||||||
100.000Hz - 999.999Hz, 1mHz | ||||||||
1.00000kHz - 9.99999kHz, 10mHz | ||||||||
10.0000kHz - 99.9999kHz, 0.1Hz | ||||||||
100.000kHz - 999.999kHz, 1Hz | ||||||||
1.00000MHz - 2.00000MHz 10Hz | ||||||||
AC test signal | Rated value(ALC OFF): Set the voltage as the Hcur voltage when the test terminal is open Set the current as the Hcur current when the test terminal is short Constant value(ALC ON): Keep the voltage in DUT is the same as the set value Keep the current in DUT is the same as the set value |
|||||||
AC signal | Voltage range | 5mVrms -- 2Vrms | F≤1MHz 5mVrms-- 20Vrms F >1MHz 5mVrms -- 15Vrms |
5mVrms -- 2Vrms | ||||
Resolution | 5mVrms -- 0.2Vrms, 100μVrms | |||||||
0.2Vrms -- 0.5Vrms, 200μVrms | ||||||||
0.5Vrms -- 1Vrms, 500μVrms | ||||||||
1Vrms -- 2Vrms, 1mVrms | ||||||||
2Vrms -- 5Vrms, 2mVrms | ||||||||
5Vrms -- 10Vrms, 5mVrms | ||||||||
10Vrms -- 20Vrms, 10mVrms | ||||||||
Current range | 50μArms -- 20mArms | 50μArms --100mArms | 50μArms -- 20mArms | |||||
Resolution | 50μArms -- 2mArms, 1 μArms | |||||||
2mArms -- 5mArms, 2 μArms | ||||||||
5mArms -- 10mArms, 5 μArms | ||||||||
10mArms -- 20mArms, 10μArms | ||||||||
20mArms -- 50mArms, 20μArms | ||||||||
50mArms--100mArms, 50μArms | ||||||||
Rdc test | Voltage range | 100mV — 2V | ||||||
Resolution | 100μV | |||||||
Current range | 0mA— 20mA | |||||||
Resolution | 1μA | |||||||
DC Bias | Voltage range | 0V — ± 10V | 0V — ± 40V | 0V — ± 10V | ||||
Resolution | 0V -- 5V, 100μV | |||||||
5V -- 10V, 1mV | ||||||||
10V -- 20V, 2mV | ||||||||
20V -- 40V, 5mV | ||||||||
Current range | 0mA— ± 100mA | |||||||
Resolution | 0 A -- 50mA, 1μA | |||||||
50mA -- 100mA, 10μA | ||||||||
Voltage source | Voltage range | - | -10V -- 10V | - | ||||
Resolution | - | 1mV | - | |||||
Current range | - | -45mA -- +45mA | - | |||||
Output impedance | - | 100Ω | - | |||||
Display | ||||||||
Dimensions / typ | 7-inch (diagonal)TFT LCD display | |||||||
Proportion | 16:9 | |||||||
Resolution | 800×RGB×480 | |||||||
Test function | ||||||||
Test parameter | Cp-D,Cp-Q,Cp-G,Cp-Rp Cs-D,Cs-Q,Cs-Rs Lp-D, Lp-Q, Lp-G, Lp-Rp, Lp-Rdc Ls-D, Ls-Q, Ls-Rs, Ls-Rdc, Rdc R-X, Z-θd, Z-θr G-B, Y-θd, Y-θr Vdc-Idc |
|||||||
Mathematics function | A(X+B)+C, X is test parameter, A, B,C is input parameter | |||||||
Equivalent circuit | Series, parallel | |||||||
Deviation measurement | Absolute deviation Δ compared with the nominal value Percentage deviation Δ% compared with the nominal value |
|||||||
Calibration function | OPEN, SHORT, LOAD | |||||||
Range selection | AUTO, HOLD | |||||||
Range | LCR | 100mΩ, 1Ω, 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10kΩ, 20kΩ, 50kΩ, 100kΩ, total 15 ranges |
||||||
Rdc | 1Ω, 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10kΩ, 20kΩ, 50kΩ, 100kΩ, total 15 ranges | |||||||
Trigger mode | INT, MAN, EXT, BUS | |||||||
Trigger delay | 0 s -- 999 s, resolution 100us | |||||||
Test terminal configuration | Four-pair | |||||||
Test cable length | 0m, 1m | |||||||
Test average | 1-255 times | |||||||
Test time (ms) | Speed mode | 20Hz | 100Hz | 1kHz | 10kHz | 100kHz | 1MHz | 2MHz |
FAST | 330 | 100 | 20 | 7.7 | 5.7 | 5.6 | 5.6 | |
MED | 380 | 180 | 110 | 92 | 89 | 88 | 88 | |
LONG | 480 | 300 | 240 | 230 | 220 | 220 | 220 | |
Test display range a 1×10 ^-18; E 1×10^18 | ||||||||
Cs, Cp | ±1.000000 aF -- 999.9999 EF | |||||||
Ls,Lp | ±1.000000 aH -- 999.9999 EH | |||||||
D | ±0.000001 -- 9.999999 | |||||||
Q | ±0.01 -- 99999.99 | |||||||
R, Rs, Rp, X, Z, Rdc | ±1.000000 aΩ -- 999.9999 EΩ | |||||||
G,B,Y | ±1. 000000 aS -- 999.9999 ES | |||||||
Vdc | ±1.000000 aV -- 999.9999 EV | |||||||
Idc | ±1.000000 aA -- 999.9999 EA | |||||||
θ r | ±1.000000 a rad -- 3.141593 rad | |||||||
θ d | ±0.0001 deg -- 180.0000 deg | |||||||
Δ% | ±0.0001% -- 999.9999% | |||||||
t | -99.99°C -- 1000.00°C | |||||||
Turn Ratio (extension pending) | ±0.000000 -- 1000.000 | |||||||
Basic test accuracy | 0.05% (the details refer to the instruction) | |||||||
List sweep | ||||||||
Sweep points | Up to 201 points | |||||||
Sweep Parameters | Test frequency, AC voltage, AC current, DC BIAS voltage, DC BIAS current | |||||||
Trigger mode | SEQ | Once triggered, test at the sweep points. /EOM/INDEX will be output one time. | ||||||
STEP | Once triggered, test at one sweep point. /EOM/INDEX will be output at each point, but the list sweep comparator results only be output at the last /EOM. |
|||||||
List sweep comparator | Set one pair of lower limit and upper limit for each sweep point. Optional: judge through the first sweep parameter / judge through the second sweep parameter / not used in each limit. |
|||||||
List sweep time tag | In SEQ mode, set the trigger point to 0, by defining the time, the test start time can be recorded at each measurement point. |
|||||||
Graph sweep analysis | ||||||||
Sweep points | 51, 101, 201, 401 or 801 | - | ||||||
Sweep trace | Primary or secondary parameters | - | ||||||
Display range | AUTO, HOLD | - | ||||||
Coordinate scale | Logarithm, linearity | - | ||||||
Sweep parameters | Test frequency, ACV, ACI, DCV BIAS/DCI BIAS, DC voltage source | - | ||||||
Sweep result display | Maximum value/ minimum value of primary/secondary parameter, primary/secondary value of the setting point |
- | ||||||
Sweep graph storage | Sweep graphs can be saved to the interior FLASH, external USB storage or uploaded to the upper computer. |
- | ||||||
Comparator | ||||||||
Bin sorting | Primary parameter |
9 BIN, OUT_OF_BINS, AUX_BIN, LOW_C_REJECT | ||||||
Secondary parameter |
HIGH, IN, LOW | |||||||
Bin limit setup | Absolute value, deviation value, percentage deviation value | |||||||
Bin count | 0 -- 999999 | |||||||
PASS/FAIL indication | When the primary parameter is one of the 9 BINs and the secondary parameter is IN, the PASS light on the front panel is ON, or FAIL light is ON. |
|||||||
Test auxiliary function | ||||||||
Data buffer storage function | 201 test results can be read in batches | |||||||
Storage/Calling function | 100 groups of test setting files in the internal nonvolatile memory 0--99 100 groups of test setting files in the USB storage 0—99 |
|||||||
Keyboard lockout function | Front panel keys can be locked | |||||||
USB HOST port | Universal Serial Bus socket, A class; FAT16/FAT32 format. USB flash disk storage or barcode scanning |
|||||||
USB DEVICE port | Universal Serial Bus socket, small size B class (4 contact position); Correspond to USBTMC-USB488 and USB 2.0 The female joint is used for connecting the external control unit. |
|||||||
LAN | 10/100BaseT Ethernet, 8pins, two selectable speed mode | |||||||
HANDLER interface | Be used for bin sorting signal output | |||||||
External DC BIAS control | Control TH1778/TH1778S Bias current source, at most 1 set of TH1778+5 sets of TH1778S (120A MAX) |
|||||||
RS232 | ||||||||
GPIB (option) | 24 pin D-Sub port (D-24 class), the female joint is compatible with IEEE488.1, 2 and SCPI. | |||||||
SCANNER |
Related products
- DC Bias Current Source: 0A up to 120A
- Output voltage 0 - 35V
- Frequency bandwidth: 50Hz - 200Hz
- Accuracy: 1%
- Resolution up to: 5mA
- For wide range of LCR Meter
- Inductor core test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- Devices: ST2830, ST2827, ST2829
- Distance between the BNC sockets: 22mm
- Cable length: 0.8m
- Adapter for zero calibration to actual component size
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 42V DC
- 4-Wire-Kelvin-Test-Leads
- Sophisticated BNC plugs
- distance between the BNC sockets: 22mm
- Alligator style clips (red / black)
- Gilded contacts
- For multimeter and LCR Meters
- Standard-compliant, multi-vendor calibration based onISO 17025
- Measuring devices: VDE devices, LCR meter, safety tester, bridges, ...
- Traceable to DKD
- Cleaning and adjustment
- Repair service
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 100V DC
- Extension of GPIB interface
- For hipot tester,
Impedanz analyzer, ohmmeter,
LCR meter, multimeter
- Inserts for test fixture ST26005B
- Measuring of axial components
- LCR meter with test fixture
- SMD test fixture
- RLC 4-wire-Kelvin method
- For precise measurement