Compact LCR Meter ST2832
€1,850.00*
Details
+49 421 277 9999
Highlights
- Frequencies: 20Hz - 200kHz
- Basic Accuracy: 0.05%
- Test parameter: |Z|, |Y|, C, L, D, Q, θ(DEG), θ(RAD), Δ%, DCR
- 4.3" TFT LCD-display
- Interface: RS232, USB, HANDLER, GPIB (optional)
- Measuring time: 13ms
- Auto-Power-On Function
- Comparator function
Specification
- 4.3"TFT LCD Display
- Soft power switch
- Max. 200kHz test frequency
- 6 digit reading resolution
- 10mVrms-2.0Vrms programmable test level
- Internal 0 - ± 5V/50mA bias source
- DCR, 50mV-2V programmable test level, resolution 10μΩ
- DCR polarity alternating to avoid magnetisation of inductors
- Highest test speed 13ms/time
- Selectable 30Ω/100Ω signal source impedance
- V/I monitor and auto level adjustment function
- Built-in comparator, 10 bins sorting and count function
- File storage and program update through U disk
- RS232, USB, HANDLER, GPIB interface (optional)
Measurement display ranges
|Z|, R, X, DCR: | 0.00001Ω - 99.9999MΩ |
|Y|, G, B: | 0.00001nS - 99.9999S |
L: | 0.00001µ - 9.9999kH |
C: | 0.00001pF - 9.99999F |
Q: | 0.0001 - 99999 |
D: | 0.00001 - 9.99999 |
θ(DEG): | -179.999° - 179.999° |
θ(RAD): | -3.14159° - 3.14159° |
Δ%: | -999.999° - 999.999° |
What's in the box
- ST26010 Gilded shorting plate
- ST26011C 4-terminal Kelvin clip test leads
- ST26048A 4-terminal test fixture
- Operation manual (as PDF for download)
- Power cord
- DE - ST2832 Datenblatt (372.47 KB)
- EN - ST2832 Data Sheet (373.25 KB)
- DE - ST2832 Bedienungsanleitung (3.08 MB)
- EN - ST2832 User Manual (1.7 MB)
Technical specification |
||||
Model | ST2830 | ST2831 | ST2832 | |
Basic measurement accuracy |
LCRZ | 0.05% | 0.1% | 0.05% |
DCR | 0.1% | |||
Calibration condition | Warm up time: ≥ 30 s ; Environment temperature: 23±5ºC Signal voltage: 0.3Vrms - 1Vrms ; Correction: after OPEN, SHORT Testing cable length: 0 m |
|||
Basic measurement accuracy |
LCRZ | 0.05% | 0.1% | 0.05% |
DCR | 0.1% | |||
Calibration condition | Warm up time: ≥ 30 s ; Environment temperature: 23±5ºC Signal voltage: 0.3Vrms - 1Vrms ; Correction: after OPEN, SHORT Testing cable length: 0 m |
|||
Test signal frequency | 50Hz-100kHz 34 points 50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz, 500Hz, 600Hz, 750Hz, 1kHz, 1.2kHz, 1.5kHz, 2kHz, 2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz, 10kHz, 12kHz, 15kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz, 75kHz, 100kHz |
50Hz-200kHz 37 points 50Hz, 60Hz, 75Hz, 100Hz, 120Hz, 150Hz, 200Hz, 250Hz, 300Hz, 400Hz, 500Hz, 600Hz, 750Hz, 1kHz, 1.2kHz, 1.5kHz, 2kHz, 2.5kHz, 3kHz, 4kHz, 5kHz, 6kHz, 7.5kHz, 10kHz, 12kHz, 15kHz, 20kHz, 25kHz, 30kHz, 40kHz, 50kHz, 60kHz, 75kHz, 100kHz,120kHz, 150kHz, 200kHz |
20Hz-200kHz, 15025 points | |
Signal source output impedance | Selectable 30Ω, 100Ω, ±1% @1kHz | |||
AC test signal level | Normal | 10mV - 2Vrms | ||
Resolution: 10mV, Accuracy: 10% x setting voltage+2mV |
||||
100µA - 20mArms | ||||
Resolution: 0.1mA | ||||
Constant Level (ALC ON) |
- | - | 20mV - 1Vrms | |
- | - | Resolution: 10mV Accuracy: 10% |
||
- | - | 200µA - 10mArms | ||
- | - | Resolution: 0.1mA | ||
DCR test signal level | 1V DC | 1V DC | 50mV - 2V DC | |
- | - | Resolution: 0.5mV | ||
DC bias voltage source | - | - | 0V - ±5V | |
- | - | Resolution: 0.5mV, Accuracy: 1% |
||
- | - | 0mA - ±50mA | ||
- | - | Resolution: 0.5µA | ||
Test parameters | |Z|, |Y|, C, L, X, B, R, G, D, Q, θ, DCR | |||
DCR display range | 0.00001Ω - 999.999MΩ | |||
LCR parameters display range | |Z|, R, X 0.00001Ω — 99.9999MΩ |Y|, G, B 0.00001μs — 99.9999s C 0.00001pF — 9.99999F L 0.00001μH — 99.9999kH D 0.00001 — 9.99999 Q 0.00001 — 99999.9 θ(DEG) -179.999º — 179.999º θ(RAD) -3.14159 — 3.14159 Δ% -999.999% — 999.999% |
|||
Display digits | 6 | 5 | 6 | |
Measurement time (≥10 kHz) | Fast: 75 meas/sec (13ms) Medium 11 meas/sec 90 ms) Slow: 2.7meas/sec 370 ms) |
|||
Equivalent circuit | Serial, Parallel | |||
Range mode | Auto, Hold | |||
Trigger mode | Internal, Manual, External, Bus | |||
Averaging | 1 - 255 individual measurements | |||
Correction | Open, Short, (known) Load | |||
Math operation | Direct reading, difference to set reference value as ΔABS, Δ% | |||
Trigger delay time setting | 0 - 60.000s, 1ms steps | |||
Step delay time setting | 0 - 60.000s, 1ms steps | |||
List Sweep |
|
|||
Comparator function | 10 bins, BIN1–BIN9, NG, AUX | |||
Bin count function | ||||
PASS, FAIL front panel or scan fixture LED display | ||||
Built-in Storage | Internal 40 LCRZ instrument setting files, 201 times test results | |||
USB Storage | Instrument setting files , measurement result CSV files, screenshots (GIF format) | |||
Interface | Control interface | HANDLER | ||
Communication interface |
USB DEVICE, RS232C, GPIB (option) | |||
Storage interface | USB HOST (U-disk storage) |
Related products
- Standard-compliant, multi-vendor calibration based onISO 17025
- Measuring devices: VDE devices, LCR meter, safety tester, bridges, ...
- Traceable to DKD
- Cleaning and adjustment
- Repair service
- Plug & Play Ansteuerung für Sourcetronic LCR Messgeräte
- Komplette Fernsteuerung der Messgeräte
- Komfortable Oberfläche im JAVA "look&feel"
- Automatisch skalierende graphische Kurven-Verläufe
- Linear & logarithmisch
- Extra "Live"-Daten Fenster
- Automatische Nullkalibrierung Short / Open
- Spezialfunktion "Frequency Sweep in graphischer Darstellung
- Benutzerdefinierbarer Grenzwertvergleich
- Robust 19" mounting frame
- Metal powder coated
- Device mounting front side
- Devices: ST2830, ST2515, ST2683, ST2516
- Color: RAL7035 light gray
- Height: 3 HE
- Golden shorting plate
- Measuring device zero claibration
- For all LCR test fixture
- Frequency up to 300kHz
- Kelvin Clip Terminal for precise LCR measurement
- 4 BNC Connectors
- Cable length: 0.8 m
- distance between the BNC sockets: 22mm
- 2 sturdy tong contacts
- Fine tooth profile gold plate brass
- No ferromagnetic parts
- Can be used with commercial LCR bridges
- 4-Wire-Kelvin-Test-Leads
- Sophisticated BNC plugs
- distance between the BNC sockets: 22mm
- Alligator style clips (red / black)
- Gilded contacts
- For multimeter and LCR Meters
- Inductor core test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- Devices: ST2830, ST2827, ST2829
- Distance between the BNC sockets: 22mm
- Cable length: 0.8m
- Adapter for zero calibration to actual component size
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 42V DC
- SMD test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- Devices: LCR Meter ST2830, ST2832
- Robust transport case
- Aluminium frame lid can be opened
- Equipment compartment with punctual foam lining
- Clearly arranged accessory compartments
- Highest transport safety
- 2 central butterfly locks at the front
- 2 locking hinges at the rear
- 1 HighEnd case handle at the front
- DC Bias Current Source: 0A up to 120A
- Output voltage 0 - 35V
- Frequency bandwidth: 50Hz - 200Hz
- Accuracy: 1%
- Resolution up to: 5mA
- For wide range of LCR Meter
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 100V DC
- Extension of GPIB interface
- For hipot tester,
Impedanz analyzer, ohmmeter,
LCR meter, multimeter
- Inserts for test fixture ST26005B
- Measuring of axial components
- LCR meter with test fixture