LCR Meter ST2826
Price on request
Details
+49 421 277 9999
Highlights
- Frequencies: 20Hz - 5MHz
- Basic accuracy: 0.1 %
- Test parameters: C, L, R,Z,Y,X,B, G, D, Q, θ, DCR
- 320x240 backlight LCD-display
- Interface: LAN, USB, RS232, Handler, (GPIB optional)
- Measurig time: 5ms
- Comparator function
Technical data
- Test Level: f≤1MHz 10mV–5V,±(10%+10mV) / f>1MHz 10mV–1V,±(20%+10mV)
- Output impedance: 10Ω, 30Ω, 50Ω, 100Ω
- Calibration function: open / short / load
- Equivalent mode: serial, parallel
- Ranging mode: Auto and hold
- Display mode: Direct, ABS, Rel
- Trigger Mode: Internal, manual, external, BUS
- Internal DC bias voltage mode: -5V – +5V,±(10%+10mV), with the resolution of 1mV
- Internal DC bias current mode:
(internal resistance is 50Ω) -100mA – +100mA, ±(10%+0.2mA), with the resolution of 20uA - Comparator function 10 bins and bin counters
- Display: 320×240 dot-matrix LCD
- Memory: 20 groups of control settings can be saved
- Interface: USBDEVICE (USBTMC and USBCDC support), USBHOST(FAT16 and FAT32 support), LAN(LXI class C support), RS232C, HANDLER
- Power supply: Voltage: 99V−121V,198V−242V / Frequency: 47.5Hz−63Hz
- Working Temperature & Humidity: 0°C − 40°C, ≤90%RH
- Dimensions (W/H/D): 400/132/385 mm
- Weight: 10kg
- CE-conformity: EN 50 191
Measurement display ranges
|Z|, R, X, DCR: | 0.0001Ω - 99.999MΩ |
|Y|, G, B: | 0.0001nS - 99.999S |
L: | 0.0001µ - 9.9999kH |
C: | 0.0001pF - 9.9999F |
Q: | 0.0001 - 99999 |
D: | 0.00001 - 9.99999 |
θ: | -179.999° - 179.999° |
What's in the box
- ST26010 Gilded shorting plate
- ST26011B Kelvin-Terminal-Test-Leads (click picture)
- ST26048 terminal test fixture
- Operation manual
- Power cord
- EN - ST2826 User Manual (1.87 MB)
Specifications |
||
Measurement Parameters | C, L, R,Z,Y,X,B, G, D, Q, θ,DCR | |
Test frequency | ST2826 | 20Hz-5MHz,with the resolution of 10mHz |
ST2826A | 20Hz-2MHz,with the resolution of 10mHz | |
Test Level | f≤1MHz | 10mV-5V,±(10%+10mV) |
f>1MHz | 10mV-1V,±(20%+10mV) | |
Output impedance | 10Ω, 30Ω, 50Ω, 100Ω | |
Basic Accuracy | 0.1% | |
Display Range | L | 0.0001 uH - 9.9999kH |
C | 0.0001 pF - 9.9999F | |
R,X,Z,DCR | 0.0001 Ω - 99.999 MΩ | |
Y, B, G | 0.0001 nS - 99.999 S | |
D | 0.0001 - 9.9999 | |
Q | 0.0001 - 99999 | |
θ | -179.99° - 179.99° | |
Measuring Speed (meas/sec) | Fast: 200(f>30kHz),100(f>1kHz) Med: 25, Slow: 5 | |
Calibration function | Open/Shot/load | |
Equivalent mode | Serial,Parallel | |
Ranging Mode | Auto and Hold | |
Display Mode | Direct, ABS, Rel | |
Trigger Mode | Internal,Manual,External,BUS | |
Internal DC bias source | Voltage mode | -5V - +5V,±(10%+10mV), with the resolution of 1mV |
Current mode (internal resistance is 50Ω) | -100mA - +100mA, ±(10%+0.2mA), with the resolution of 20uA | |
Comparator function | 10 bins and bin counters | |
Display | 320x240 dot-matrix LCD display | |
Memory | 20 groups of control settings can be saved | |
Interface | USB DEVICE( USBTMC and USBCDC support) | |
USB HOST(FAT16 and FAT32 support) | ||
LAN(LXI class C support) | ||
RS232C | ||
HANDLER | ||
GPIB(option) | ||
General Specifications |
||
Working Temperature & Humidity | 0°C - 40°C, ≤90%RH | |
Power supply | Voltage | 99V-121V,198V-242V |
Frequency | 47.5Hz-63Hz | |
Power Consumption | ≤ 80VA | |
Dimensions (WxHxD) | 400mmx132mmx385mm | |
Weight | Approx. 10kg |
Related products
- 4-Wire-Kelvin-Test-Leads
- Sophisticated BNC plugs
- distance between the BNC sockets: 22mm
- Alligator style clips (red / black)
- Gilded contacts
- For multimeter and LCR Meters
- Standard-compliant, multi-vendor calibration based onISO 17025
- Measuring devices: VDE devices, LCR meter, safety tester, bridges, ...
- Traceable to DKD
- Cleaning and adjustment
- Repair service
- Devices: ST2830, ST2827, ST2829
- Distance between the BNC sockets: 22mm
- Cable length: 0.8m
- Adapter for zero calibration to actual component size
- Golden shorting plate
- Measuring device zero claibration
- For all LCR test fixture
- Frequency up to 5MHz
- Kelvin Clip Terminal for precise LCR measurement
- 4 BNC Connectors
- 2 sturdy tong contacts
- Fine tooth profile gold plate brass
- No ferromagentic parts
- Can be used with commercial LCR bridges
- Comfortable measurement software with special functions
- "Frequency Sweep" / "Analyzer Function"
- Data display, data logging, analysis, report
- Runtime chart, e.g. cooling curves
- Language: English / German
- Communication via RS-232 and USB
- Export file: CSV, Excel
- Application upgrade in order to your requirements
- Extension of GPIB interface
- For hipot tester,
Impedanz analyzer, ohmmeter,
LCR meter, multimeter
- Compatible with wired LCR Meter
- 4-Terminal fixture
- BNC connectors
- Gilded contacts
- Max peak voltage 42V DC
- SMD test fixture
- RLC 4-wire-Kelvin method
- For precise measurement
- 4-wire technology
- Kelvin-leads with BNC-Terminal
- Isolation of soft PVC
- Multi colored cable (red and black)
- Strain relief and bend protection