Insulation Tester ST2684A
Product number:
60822
EAN:
4260254479168
€3,100.00*
Goods expected soon
Details
Fachberatung unter
+49 421 277 9999
+49 421 277 9999
Print
Description
Product information "Insulation Tester ST2684A"
Highlights
- High precision Insulationtester
- 320x420 dot-Matrix LCD
- Powerful charging function
- High speed measurement: 100meas/sec
- Contact detection function for capacitive components
- 7 current ranges, manual or auto range mode
- 4-bin comparison function
- Programmable sequence test mode
- R-T and I-T curce test and display mode
- Auto store setup parameters
- Screenshot can be saved to USB disk
- Remote control via RS232 or USB
Test methods
Resistance test
- Range: 10kΩ to 100TΩ
- Accuracy:
- Test current > 100pA: 2%
- Test current ≤ 100pA: ±5% ±Rtest/ (Vtest/3pA)
Current test
- Ranges:
- Range1: 100μA - 1mA / Internal input impedance 10kΩ
- Range2: 10μA - 100μA / Internal input impedance 10kΩ
- Range3: 1μA - 10μA / Internal input impedance 10kΩ
- Range4: 100nA - 100μA / Internal input impedance 10kΩ
- Range5: 10nA - 100nA / Internal input impedance 10kΩ
- Range6: 1nA - 10nA / Internal input impedance 1MΩ
- Range7: 10pA - 1nA / Internal input impedance 1MΩ
- Accuracy: 2% ± 2pA
Measurement voltage
- Range: 10V - 1000V
- Accuracy: 2% of readout, or ± 1V
- Source resistance: 200Ω
- Current limit: 2mA, 25mA or 200mA
- Voltage output: Manually turn on/off on front panel or controlled by built-in time, or by remote control
- Timing: Programmable charge time: 0 to 1000s
- Measurement delay: 0 to 1000s programmable
- Discharge resistance: 2kΩ
- Discharge time: t=0.03 x C[&muF], when Vtest falls to 1% of the test level
Technical data
- Trigger mode: Single, Average up to 100 times or continuously
- Comparator: 4 bins:(3 bins for PASS, 1 bin for FAIL)
- Range mode: Auto, hold
- Average times: 1 to 100
- Memory: 20 sets of setup values can be stored.
- Interface: RS232C, HANDLER, USB, SCANNER
- Operating temperature: 10°C - 40°C
- Humidity: ≤ 90% RH
- Power supply:
- 90V to 130V AC (60Hz) - 198V to 260V AC (50Hz)
- Power consumption: 150W
- Dimensions (WxHxD): 430mm x 400mm x 130mm
- Weight: 14kg
What's in the box
- ST26004B 2-terminal test clip leads
- Operation manual
- Power cable
Downloads
- EN - ST2684A User Manual (1.58 MB)
Software
Technical data
Specification |
||
Model | ST2684 | ST2684A |
Resistance test |
||
Test range | 10kΩ - 50TΩ | 10kΩ - 100TΩ |
Test accuracy | I>100pA : ±2% I≤100pA : ±2% ±Vtest/2pA |
|
Current test |
||
Test range | Range 1: 100µA - 1mA, internal input impedance 10kΩ | |
Range 2: 10µA - 100µA, internal input impedance 10kΩ | ||
Range 3: 1µA - 10µA, internal input impedance 10kΩ | ||
Range 4: 100nA - 1µA, internal input impedance 10kΩ | ||
Range 5: 10nA - 100nA, internal input impedance 10kΩ | ||
Range 6: 1nA - 10nA, internal input impedance 10kΩ or 1MΩ | ||
Range 7: 10pA - 1nA, internal input impedance 10kΩ or 1MΩ | ||
Test accuracy | 2% ± 2pA | |
Test voltage |
||
Range | 1V - 500V, 1V resolution | 1V - 1000V, 1V resolution |
Accuracy | 2% of readout,or ± 1V | |
Source resistance | 200Ω | |
Current limit | 2.25 or 200mA | 2.25 or 100mA |
Voltage Output | Manually turn on or off it on front panel, or controlled by built-in timer, or by remote control | |
Charge time | 0 - 999s programmable | |
Measurement delay | 0 - 999s programmable | |
Discharge resistance | 2kΩ | |
Discharge time | t = 0.03 x Cx (in µF), when Vtest falls to 1% of the test level. | |
Measurement speed |
||
Trig mode | Single measurement: < 100ms(exclude charge time) Average up to 100 measurements:<100 + (N-1) x 100 ms (exclude charge) | |
Continous mode | Direct readout: 100ms – 10000ms depending on average number | |
Comparator function | 4 bins: 3 bins for PASS, 1 bin for FAIL | |
Range mode | Auto, Hold | |
Average times | 1 - 100 | |
Memory | Internal memory and external USB disk | |
Standard interface | GPIB, (optional); RS232C; HANDLER interface output; USBDEVICE( USBTMC and USBCDC support); USBHOST; SCANNING |
General Specifications |
|
Operating Temperature and Humidity | 10°C - 40°C, ≤90%RH |
Power supply | 90 to 130 V AC(60Hz) or 198 to 260V AC(50HZ) |
Power Consumption | ST2684: 250W ST2684A: 150W |
Dimensions (WxHxD) | 430mmx400mmx130mm |
Weight | ST2684: 14kg ST2684A: 10kg |
Related products
2-Wire Relay Matrix STM
€4,950.00*
- Robust 2-wire matrix
- Measuring points freely connectable
- Test connection via Harting plug
- Continuity tests
- High voltage tests
- Insulation resistance tests
- Surge voltage tests
ST®Meter 3.0 Plus
€289.00*
- Comfortable measurement software with special functions
- "Frequency Sweep" / "Analyzer Function"
- Data display, data logging, analysis, report
- Runtime chart, e.g. cooling curves
- Language: English / German
- Communication via RS-232 and USB
- Export file: CSV, Excel
- Application upgrade in order to your requirements
Calibration Insulation Tester
€79.00*
- Standard-compliant, multi-vendor calibration based onISO 17025
- Several measurement ranges
- Insulation tester
- Traceable to DKD
- Cleaning and adjustment
- Repair service
2-Terminal Test Clip Leads ST26004B
€38.00*
- 2-Wire-Test-Leads
- High quality BNC plugs
- Alligator style clips (red / black)