Hipot Tester UX36-ADC-1014-0100-TPT
Price on request
Details
+49 421 277 9999
Hipot Tester UX36-ADC-1014-0100-TPT
The UX36-1014 hipot tester is a version of the UX-series test sets with 10´kV AC and 14kV DC. The units of the UX series are available in an elegant industrial housing including high-voltage equipment, as well as test adapter, 2-hand operation and safety precautions.
Highlights
- 10kV AC and 14kV DC (selectable)
- Ramp programable
- 4-wire-contact monitoring
- Wire break monitoring
- Launch control
- Programmable test parameters
- RS232, digital I/O (SPS), CAN
- Software, DLL, LabView, Active-X (option)
Test methods
- High voltage test AC
- AC voltage: 500 V - 10.000 V
- AC current: 0.5 - 100 mA
- Short circuit current: 200 mA
- Transformer capacity: 1000 VA
- Output frequency 50 Hz / 60 Hz
- High voltage test DC
- DC voltage: 500 V - 14.000 V
- DC current: 0.5 - 70 mA
- Short circuit current: 200 mA
- Transformer power: 1000VA
Technical data
- Desktop unit with dry-type transformer
- Potential free (suitable for use with test probes)
- Regulated test voltage
- Burning function in AC mode
- High voltage output on the rear side
- Error message: acoustic, optical, interface
- Zero voltage switch(to conserve test object)
- ACTUAL- and SET POINT-display (current/voltage)
- Max. 1 sec. Burning function (AC)
- Keyboard lock
- Acoustic signaling adjustable
- Display brightness control
- Start mode selectable
- Data management program with your PC (optional)
- Ramp times and ramp types
- Verifying time scaling
- Test time: 1-99s / 1-99 minutes and infinitely
- Minimum current monitoring
- Integrated program memory
- Large LED display and various control buttons
- CAN bus for expansions
- Digital I/O:
- START / STOP
- PASS / FAIL
- Test in progress
- Terminals:
- 2 HV sockets potential free
- Warning lamp
- Foot switch, test-cage, light curtain, prod.-line, two-hand-operation
- Highest safety standard:
- Key switch preventing unauthorized use
- High voltage absolutely potential-free
- Two fold isolated transformer and measurement converter
- Status indication
- Socket for external pilot lamp
- Integrated warning buzzer
- Insulated sockets
- Security activation knob in compliance with VDE0104
- Safety Circuit with forcibly actuated HV relays
- Power supply: 230V, 50/60 Hz, 8A max.
- Operating temperature: +5° to +45°
- Humidity: 70% (non condensing)
- Height: 2000 m above NN
- Compact industrial housing (RAL 7035)
- Dimensions (W/H/D): 590/210/540 mm
- Weight: 20 kg
- CE-conformity, according to EN 50 191
What's in the box
- Interlock connector
- Key set
- Power cable
- Operation manual
- Factory calibration
Options
- KANON12-025 High voltage test pistols
- HVP16C HV cable with plug
- KLD-SW alligator clips black
- WK36 Warning lights set
Related products
- Devices: hipot testers 36 series
- Signal lamp: red / green
- Conforming to all standards: VDE0104, EN50191
- Status:
- READY FOR OPERATION
- READY TO SWITCH ON
- IN OPERATION
- Voltage: 230V
- Cable length: 2m
- Conforming to all standards
- Emergency stop for tester
- Load: 16 A
- Cable length: 5 m
- Devices: 28, 36 & 400
- Wide grip: brass
- Toothed jaws
- Bonding: 30 mm
- For laminated plug
- Rectangle design
- "No unauthorised entry"
- Material: plactic
- Size: 200mm x 300mm
- Colour: red/white
- Portable posts chain
- Convex base plate
- Colour: Yellow-Black
- Two-parts
- Height: 1100mm / D=32cm
- Devices: 36 series
- Mounted on test trolley
- Total hight of lamps 1850mm
- Standard: EN 50191, VDE0104
- Lights: Red/Green
- Function: operation, switch on, ready
- Cable length: 2m
- All-Round-Test-Cage to connect
with safety testers and hipot testers - Dimension (W/H/D):
Outside: 670 / 515 / 495 mm
Inside: 565 / 350 / 450 mm - Viewable transparent swinging hood
- Damping gas spring
- Safety limit switch
- CE conform with EN 50191
- HV Tester: UB36, UG36, UH36, UX36
- With foot protection cover
- Start via control-IO
- With plug: SUB-D 9-pole
- Access to control interface
- Cable length: 2m
- All-Round-Test-Cage to connect
with safety testers and hipot testers - Dimension (W/H/D):
Outside: 450 / 515 / 495 mm
Inside: 360 / 350 / 450 mm - Viewable transparent swinging hood
- Damping gas spring
- Safety limit switch
- CE conform with EN 50191
- HV-Cable, single-pole
- Length 3 m
- HV-plug HIRAT
- 16 kV AC / 22 kV DC, max. 10 A
- Max. 100 kV AC
- Max. 140 kV DC
- Unloading bars accordingly: VDE 0681 part 1, VDE 0681 part 2, VDE 0681 part 3, VDE 0683 part 100
- Standard-compliant, multi-vendor calibration based on ISO 17025
- Hipot and Insulationtester
- Traceable to DKD
- Cleaning and adjustment
- Repair service
- Devices: series 36 & 400
- Complete library
- License for 1 test system
- Including CD with drivers and manual
- Triangle design
- With flash arrow
- Material: plactic
- Size: 200mm x 200mm
- Colour: yellow/black
- DIN 40008
- Log printer in own plastic table casing
- Not to be built-in.
- Baud rate 9600
- Rectangle design
- "Danger High Voltage"
- Material: plactic
- Size: 74mm x 210mm
- Colour: yellow/black
- EN50191 / DIN 40008
- Including cable-set for hipot tester:
36 series (UH36/UX36) - Ergonomically design
- Push-start-buttons: 2
- Normed distance between buttons
- Connecting cable: 2.5 m
- HV Tester: UB36, UG36, UH36, UX36
- Start via control-IO
- With plug: SUB-D 9-pole
- Access to control interface
- Cable length: 2m
- Single-pole, in conduit
- Length 2,5 m
- HV-plug HIRAT
- 16 kV AC / 22 kV DC, max. 10 A,
- Devices: series 36 & 400
- Complete library
- License for 1 test system
- Including CD with drivers and manual
- HV-Cable, single-pole, in conduit
- Length 2,5 m
- 16 kV AC / 22 kV DC, max. 10 A