Frequency Inverter ST600 15kW 400V IP55
€869.90*
Details
+49 421 277 9999
Meets the ecodesign requirement.
Highlights
- Power: 15kW
- Input current: 40A
- Output current: 32A
-
Input frequency range: 50Hz / 60Hz ( ± 5%)
- Output frequency range: 0-400Hz
- Voltage: 380V (15%) - 440V (10%)
- IP55 protection class
- Standardized emergency stop function according to SIL2 level (STO)
- Graphical LCD control panel
- Expandable with WIFI, Bluetooth, ProfiNet/Profibus, CANopen, PG, PLC, IO
- Integrated main switch
- Integrated brake unit
- Integrated EMC filter C3
- Flexible digital and analog I/O
- Advanced PID control
- Easy intuitive commissioning and short installation
- Flexible speed adjustment with control panel buttons
- Overload capability: 1min 150% / 10 sec 180% / 1 sec 200%
- Auto slip compensation
- RS485 interface integrated (control protocol Modbus RTU standard)
- USB interface
- German interactive user manual
Inputs
Digital inputs |
|
Programmable digital inputs: | 6, of which 4x max. 1kHz (S1-S4), 2x max. 50kHz (HDIA, HDIB) with 82 input functions |
Voltage level: | 0 - 24VDC |
Logic: | PNP / NPN Factory default: PNP (active when input is connected to +24V) |
Maximum voltage at input: | 30VDC |
Number of programmable pulse inputs: | 2 (HDIA, HDIB) |
Maximum input frequency: | 50kHz, duty cycle 30 to 70% |
Resolution for frequency control: | 0.1% |
H1, H2 | Redundant inputs for connection to +24V via normally closed contacts for the STO safety function (immediate interruption of power to the drive if at least one of the connections to +24V is interrupted). In factory setting connected to +24V via shorting jumpers (STO inactive). |
Analog inputs. |
|
Number of analog inputs: | 2 |
Type of inputs: | AI 1: 0-10V / 0-20mA AI 2:-10 - +10V |
Resolution for frequency control | max. frequency * 0.05%, tolerance ±0.5%@25°C |
Outputs
Output (U,V,W) |
|
Control modes: | U/f characteristic curve / vector control o. PG / vector control w. PG |
Output voltage: | 0 - 100% of the mains supply |
Output frequency: | 0 - 400Hz (vector control or V/f - control) |
Nominal motor voltage: | 400V |
Ramp times: | 0.0 - 3600.0s |
Ramp functions: | Linear / S-curve |
Overload function: | 150% for one minute 180% for 10 seconds 200% for 1 second |
Carrier frequency: | 0.5kHz - 16.0kHz adjustable |
U/f curve modes: | Linear/Square/Adjustable |
Digital output / pulse output |
|
Programmable outputs: | 2; 1 high-speed output, max. 50kHz, 1 open-collector output, max. 1kHz 51 output functions |
Voltage level: | 24VDC, max. 30VDC, 50mA |
Logic: | NPN (output is actively pulled against COM or CME) |
Minimum output frequency: | 0Hz |
Maximum output frequency: | 50kHz |
Relay outputs |
|
Programmable outputs: | 2 |
Clamp number: | RO1A-1C and RO2A-2C: normally open RO1B-1C and RO2B-2C: normally closed |
Maximum power AC: | 250VAC / 3A |
Maximum power DC: | 30VDC / 1A |
Number of functions: | 51 |
Analog outputs |
|
Programmable outputs: | 1 |
Voltage range: | 0 - 10VDC max. 5mA |
Current range: | 0 - 20mA max. load 250Ohm |
Number of functions: | 32 |
Modbus |
|
RS485 | Integrated |
Optional |
|
The optional IO501 expansion card adds 4 digital inputs S5-S8, 1 digital output Y2, 1 analog input AI3 (0-10V/0-20mA), 1 analog output AO2 and two relay outputs |
Integrated protection concept
- IP55 protection class
- Ground fault protection
- Overvoltage and undervoltage protection
- Overcurrent protection
- Overload and underload protection
- Temperature display rectifier and IGBT output stage
- Overtemperature protection
- Overvoltage prevention during braking
- External stop signal
- Safe Torque Off (STO)
- Stop when communication is interrupted
- Detection of abnormalities in PID signal and PG error
- Input for motor temperature bimetal switch/PTC
- Password protection
- Auto self test after power on again
Display and functions
- Display:
- Frequency, current, voltage, torque, PID, ...
- Error messages
- Key lock / parameter transmission
- Languages: DE, EN
- Error messages:
- Error type
- Output and bus voltage
- Output current
- Setpoint and actual frequency
- Inverter terminal status
- Temperature
- Automatic functions:
- Calibration of the motor data
- Voltage regulation (AVR)
- Active current limiting
- Restart on power failure
- Slip compensation
Case types and dimensions
Nominal voltage |
Output
|
Nominal
|
Nominal-
|
Housing dimensions in mm(width x height x depth) |
Weight [kg]net / gross |
3-phase 400V | 15 | 40 | 32 |
223 x 475 x 289.4 |
13 / 15.4 |
Environment
- Temperature range -10°C to +40°C at rated load
- Storage temperature -20°C to +65°C
- Humidity 90% RF - without condensation
- Can be used up to 1000m above sea level without power reduction
- Vibration test below 5.9m/s²=0.6g
- Safety level according to IEC61800-5-1/2+A1
- Electromagnetic compatibility according to IEC61800-3
- Ingress protection: IP55 (EN 60529), pollution degree 2
- RoHS compliant
- CE compliant
Scope of delivery
- Frequency converter ST600
- English operating instructions
Other functions
- Nominal motor frequency 50Hz and 60Hz
- Forward and reverse operation
- Controller enable control panel/terminal/bus
- 16 configurable speed levels selectable via digital inputs
- 12 different ways to control speed
- Infinitely adjustable clock frequency: 1.2kHz-15.0kHz (PWM)
- "Open-loop boost mode"
- DC braking function (duration, strength, frequency) & JOG control
- Simultaneous control of multiple drives "Slave Vector Control"
- Reduced motor noise by precise PWM function
- Vibration prevention by selectable blocking frequencies
- Variable speed at constant torque
- "Plug & Play":
IE2 compliance
- (1) Power loss %: See "ST600 IE2 Information"
- (2) Efficiency level: "IE2" according to Section 4 of the "Ecodesign Requirements for Electric Motors and Speed Controls"
- (3) Manufacturer: Sourcetronic GmbH, HRB 26045, Fahrenheitstr. 1, 28359 Bremen
- (4) Model: ST600 G3 (400V)
- (5) Output power: See "ST600 IE2 Information"
- (6) Indicative rated output power: See "Highlights"
- (7) Rated output current: See "Highlights"
- (8) Max. Operating temperature: 40 °C without performance degradation
- (9) Rated input frequency (Hz): 50Hz / 60Hz
- (10) Rated input voltage: 380V(-15%) - 440V(+10%)
- (11) Not applicable
Bus systems |
|
Supports many common bus systems such as PROFINET, PROFIBUS as well as Modbus RTU |
Digitalization of drive technology - bus systems, Internet and maps
The frequency inverter has standard 485 communication and is flexibly expandable with PG card, PLC card, IO card, ProfiNet, Profibus, WIFI, Bluetooth, CANopen etc. The PG card uses digital filtering technologies to improve electromagnetic compatibility and enable stable reception of the encoder signal over long distances. Compared with the traditional scheme, the anti-interference performance is doubled. With 2 x HDI, high speed is achieved, moreover, high-speed AB pulse is supported as input signal.
Preventive maintenance - Continuously improve your production
Your electric motor-driven application requires reliable performance. Maximum system availability and operational reliability is achieved through tailored services, such as wireless troubleshooting via remote access or Bluetooth access using the smartphone APP. Parameter sets can be quickly read out via the USB port. Through an external uplink, the inverter's operating curve can be recorded for maintenance purposes and analysis.
Sustainability - Energy efficiency and IE2 class according to IEC 61800
The operation of electric motors accounts for up to 70% of global electricity consumption in industry. Pumps are among the most common applications and offer the greatest potential for savings. Frequency converters can help solve the challenges of the energy transition. After all, at half speed, only one-eighth of the energy is needed. You will be interested to know that Sourcetronic frequency converters already meet the most stringent requirements of the IEC 61800-9 standard for energy efficiency and are classified as IE2.
- NL - ST600 Verkorte Handleiding (2.36 MB)
- ES - ST600 Manual Abreviado (2.21 MB)
- EN - ST600 Quick Start Guide (2.28 MB)
- ST600 STEP 3D Files (43.95 MB)
- FR - ST600 Manuel Abrégé (2.28 MB)
- IT - ST600 Manuale Sintetico (2.3 MB)
- DK - ST600 Forkortet Manual (2.41 MB)
- DE - ST600 Kurzanleitung (1.66 MB)
- PL - ST600 Skrócony Podręcznik (2.29 MB)
- ST600 EPLAN Makros (1.22 MB)
- DE - ST600 Bedienungsanleitung (31.25 MB)
- EN - ST600 User Manual (17.75 MB)
Accessoires
- Telefonische Beratung
- Auslegung und Inbetriebnahme
- Individuelle Parametrierung
- Programmbetrieb
- Parameterliste
- Resistance: 40 Ω
- Rated power: 1500 W (continuous braking power with appropriate heat dissipation)
- Operating voltage range: up to 400 V
- IP Grade: IP00/IP33
- Weather resistant and vibration resistant
- Easy insatallation
- IP20 protection
- Current: 42 A (nominal current must be greater than the input current of the frequency inverter)
- Voltage: 400 V
- Category: C2
- Reduces Voltagepeaks
- Attenuates electromagnetic radiation
- Installation & Commissioning
- Configuration and parameterisation
- Switch cabinet construction
- Electrification of entire construction sites
- Frequency converter exchange
- Standard-compliant documentation
- Instruction of the operating personnel
- Consulting and design drive technology
- Project planning Electrical engineering
- E-construction ePlan P8
- Programming/visualisation (PLC/HMI/JAVA)
- Monitoring, control and regulation systems
- Sensor consulting
- Processing of tenders with focus on drive technology, automation, pump controls
- Determination of energy saving potentials
- Planning, construction, delivery and installation of control systems
- Frequency Inverter Quick Service
- Installation, commissioning, trial operation
- Instruction of the operating personnel
- Identification of error causes
- Reduction of subsequent and repeat faults
- Maintenance, servicing and retrofitting of systems
- Lifecycle management of drive technology
- Around-the-clock service": 24/7 monitoring service of plants
- Compatible with frequency inverters of the ST600 series
- Compatible with PLC Siemens S7-1200 or S7-1500 with TIA Portal V15
- The Profinet card is connected via two RJ45 sockets
- Compatible with ST600 frequency inverter series
- Recommended when using communication cards
- Enables communication with the inverter even when power supply is interrupted
- Compatible with ST600 frequency inverter series
- PROFIBUS standard: DP
- Connection via Sub-D-9 socket
- Transmission rate: 9.6kbit/s to 12Mbit/s
- Up to 32 nodes (without repeater) and 127 nodes (with repeater) in one segment of the network
- 24V power supply card SPS501-24 recommended as a supplement
- Devices: ST600
- Dimensions (W/H/D): 103/140/16.8 mm
- incl. 2m cable
- Compatible with ST600 series of frequency converters
- High resolution graphical LCD control panel
- Connection via RJ45
- Compatible with ST600 series frequency inverters
- For ABZ incremental encoders with differential, push/pull or OC output
- Voltage: 5/12VDC switchable via SW1
- 5V differential frequency divider output, configurable from 1:1-2255
- Intuitive installation thanks to plug and play: just plug in and go
- Compatible with ST600 series frequency inverters
- For ABZ incremental encoders with differential, push/pull or OC output
- Voltage: 24V
- 5V differential frequency divider output, configurable from 1:1-2255
- Intuitive installation thanks to plug and play: just plug in and go
- Compatible with ST600 series frequency inverters
- Sinusoidal encoder with/without C/D signals
- Voltage: 5VDC
- Easy installation thanks to plug and play
- Compatible with ST600 series frequency inverters
- PG card for brushless resolver
- Excitation voltage 7 VRMS, frequency 10kHz
- Recommended transfer ratio: 0.5
- Resolver output voltage 1±0.2Vpp
- 5V differential frequency divider output ABZ, configurable from 1:1-2255
- Intuitive installation thanks to plug and play: just plug in and go
- Compatible with ST600
- 4 digital inputs
- 1 digital output
- 2 relays with one normally open contact each.
- 1 connection for a PT100 temperature sensor
- 1 connection for a PT1000 temperature sensor
- Compatible with ST600
- 4 digital inputs
- 1 digital output
- 1 analog input
- 1 analog output
- 1 relay with changeover contact
- 1 relay with one normally open