To set a target frequency greater than 320Hz, it is necessary to make an resolution adjustment of the target frequency F0.02 = 1

Here is an example for a frequency of 600Hz

F0.02 = 1                Resolution of the target frequency – 0.1Hz
F0.19 = 600.0      Target frequency to 600Hz
F0.21 = 600.0      Upper frequency maximum adjusted for 600Hz

Now in the motor parameter B0.04 = 600.0 the motor frequency can be changed.